DIN 75201 Package Testing Equipment / Fogging Tester

Place of Origin China
Brand Name Labthink
Certification ISO 9001, CE
Model Number FT-F1
Minimum Order Quantity 1 set
Price Negotiable
Packaging Details Veneer Case
Delivery Time 3-7 work days
Supply Ability 1 set per 3 work days
Product Details
Standards ISO 6452, DIN 75201, SAE J1756 Test Method Gloss, Haze, Weighing Methods
High-Temperature Range Room Temperature ~ 150°C Low-Temperature Range 0 ~ 100°C
Accuracy ±0.1°C
High Light

Air Permeability Test Equipment

,

Fabric Air Permeability Tester

Leave a Message
Product Description

DIN 75201 Fogging Tester for Decorating Articles of Automotive Interior materials

 

FT-F1 fogging tester is professionally designed for the fogging characteristics evaluation of volatile constituents of decorating materials used in cars and aircrafts, e.g. plastic articles, polyurethane, textiles, leather, adhesives, nonwovens and thermal forming elastomers at high temperature conditions. It also could be used for the fogging phenomenon test of high intensity discharge (HID) headlamps of cars.

 

Specifications

Specifications FT-F1 Fogging Tester
Temperature Range of High-Temperature Bath Room temperature ~ 150°C
(room temperature ~ 280°C is optional)
Accuracy ±0.1°C (150°C)
Temperature Range of Low-Temperature Bath 0 ~ 100°C
Accuracy ±0.1°C
Size of High-Temperature Bath 670 mm (L) x 490 mm (W) x 540 mm (H)
Size of Low-Temperature Bath 400 mm (L) x 220 mm (W) x 520 mm (H)
Net Weight of High-Temperature Bath 32 kg (except the weight of heat conducting medium)
Net Weight of Low-Temperature Bath 15 kg (except the weight of heat conducting medium)
Power Supply AC 220V 50Hz

 

Test Methods

Gloss Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value could be obtained by calculating and comparing the gloss values occurred before and after condensation process.
Haze Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value of the specimen could be obtained by calculating and comparing the fogging values occurred before and after condensation process.
Weighing Method: the specimen is heated in the beaker and its volatile constituents are condensed on the cooling aluminum foil. The fogging value - the weight of condensed constituents could be obtained by analyzing the weight changes of aluminum foil occurred before and after condensation process.