Package Testing Equipment
-
WVTR Testing Equipment
-
Vacuum Leak Testing Equipment
-
Friction Testing Equipment
-
Adhesion Test Equipment
-
Tensile Testing Machine
-
Box Compression Testing Machine
-
Torque Testing Machine
-
Tear Testing Machine
-
Gas Permeability Tester
-
Heat Seal Tester
-
Falling Dart Impact Tester
-
Flex Durability Tester
-
Digital Ink Rub Tester
-
Headspace Gas Analyzer
-
Thickness Measurement Equipment
Computer Control Falling Dart Impact Tester For Packaging Sheets ASTM D1709

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xTest Method | Free Falling Dart | Standards | ASTM D1709 |
---|---|---|---|
Specimen Clamp | Pneumatic Clamp | Warranty | 12 Months |
Package | Veneer Case | ||
Highlight | Pendulum Impact Testing Machine,Pendulum Impact Tester |
Computer Control Electronic Falling Dart Impact Tester for Packaging Sheets
BMC-B1 Falling Dart Impact Tester can test the impact resistance of materials including plastic films, paper, foils, etc. by free falling dart or ball method according to ASTM F1709 (method A and method B).
Test Principle
Before starting the test, choose test method, and estimate an initial mass and Δm. Start the test. If the first
specimen fails, decrease the mass of the falling dart by Δm. If the first specimen is not a failure, increase the mass of the falling dart by Δm. Continue the test according to this rule. In brief, increase or decrease by Δm according to whether the former specimen is a failure or not. After 20 specimens, calculate the total number of failed specimens N. If N equals to 10, the test is over. If N is less than 10, add specimens and continue to test until N equals to 10. If N is greater than 10, add specimen and continue the test until the number of non-failure specimens reaches 10. Then the tester calculates the test results automatically according to specific formulas.
Technical Specifications:
Specifications | BMC-B1 |
Test Method | Method A or Method B is optional |
Test Range | Method A: 50~2000 g |
Method B: 300~2000 g | |
Accuracy | 0.1 g (0.1J) |
Specimen Clamp | Pneumatic Clamp |
Pressure of Gas Supply | 0.6 MPa (outside of supply scope) |
Port of Gas Supply | Φ8 mm PU Tubing |
Specimen Size | > 150 mm x 150 mm |
Power Supply | AC 220V 50Hz |
Net Weight | 70 kg |
Instrument Dimension | Method A: 500 mm (L) x 450 mm (W) x 1320 mm (H) |
Method B: 500 mm (L) x 450 mm (W) x 2160 mm (H) |
Applications:
1. Films
2. Aluminum Foil and Aluminum Plastic Composite Films
3. Paper and Paper Board
4. Falling Ball Test
5. Shoulder Piece Test