Package Testing Equipment
-
WVTR Testing Equipment
-
Vacuum Leak Testing Equipment
-
Friction Testing Equipment
-
Adhesion Test Equipment
-
Tensile Testing Machine
-
Box Compression Testing Machine
-
Torque Testing Machine
-
Tear Testing Machine
-
Gas Permeability Tester
-
Heat Seal Tester
-
Falling Dart Impact Tester
-
Flex Durability Tester
-
Digital Ink Rub Tester
-
Headspace Gas Analyzer
-
Thickness Measurement Equipment
Labthink Water Vapor Transmission Testing Machine

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xTest Method | Electrolytic Sensor Method | Standards | ISO 15106-3 |
---|---|---|---|
Temperature Range | 15°C~55°C (standard) | Humidity Range | 0%RH, 35%RH~90%RH, 100%RH |
Instrument Dimension | 690 Mm (L) X 350 Mm (W) X 360 Mm (H) | Net Weight | 70 Kg |
Highlight | Water Vapor Permeability Test Machine,Water Vapor Transmission Testing Equipment |
ISO 15106 Solar Back-Sheets Water Vapor Permeability Test Machine by Electrolytic Sensor Method
W3/330 Water Vapor Permeability Test Machine is based on the electrolytic sensor method to measure water vapor transmission rate of film and package specimens. It has three independent testing cells and can be easily connected with 9 satellite systems.
Features
- Wide range and high precision of temperature and humidity control to support various combinations of non-standard test conditions
- Standard, proportional and continuous testing modes facilitate to minimize errors caused by human factor during testing process
- Convenient fast-access calibration port for temperature and humidity
- Reference film for accurate calibration
- Based on the user-friendly Windows operating interface for easy operation
- Saves test data in different formats for convenient data transfer
- Intelligent historical data searching, comparing, analyzing and printing functions
- Supports LystemTM Lab Data Sharing System for uniform management of test results and test reports
Specifications
Film Test | Package Test (customization available) | |
---|---|---|
Test Range | 0.001~40 g/m2·24h (standard) 0.01~1000 g/m2·24h (optional) |
0.0001~0.2 g/pkg·d |
Number of Specimens | 1~3 with independent test results | |
Resolution | 0.001 g/m2·24h | 0.00001 g/pkg·d |
Temperature Range | 15°C~55°C (standard) | |
Temperature Accuracy | ±0.1°C (standard) | |
Humidity Range | 0%RH, 35%RH~90%RH, 100%RH | |
Humidity Accuracy | ±1%RH |